A REVIEW OF DP50RB

A Review Of Dp50rb

A Review Of Dp50rb

Blog Article

one.2.two Warning Labels Warning Labels This means Make sure you very carefully read this handbook in advance of use system. The subsequent labels absolutely are a. Usually do not put the system with a sloped surface area. If not the offered in the event the method product might slide, resulting in private harm or maybe the device performs with the cell malfunction.

The DP-fifty Expert is definitely an progressive, large-effectiveness Ultrasound Procedure engineered to assist you get the insights you will need. The Program’s effective engine and substantial-velocity processing give fantastic picture high quality and an entire data administration Option.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

NOTE: Make sure that you can pull out and push into the IO board sockets vertically when pulling out and assembling the IO board assembly over the placement in the deal with. Remove panhead screws with washers M3X6 (four) utilized to safe the IO board, and after that you could choose out the IO board. Site 116 Take out panhead screws with washers (two M3X6) which can be fixed on the leading unit, consider out the upper baffle and then pull out two cables connecting the main board to the power module assembly.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Usually do not use any cables in addition to the cables delivered Along with the system by Mindray. three. Utilize the cable provided with this system to attach the printer. Other cables may possibly bring about electric powered shock. Web page fifteen: Mechanical Safety

Effectiveness Check five.five.one Test System Resolution Detection depth Geometric Placement Precision Blackout space examination History the exam illustrations or photos five.five.2 Examination Content material The picture applied Here's just for reference, keep on with the graphic effect in the real NOTE: circumstance. Demands: Exhibit: established the contrast and brightness on the clinical software benefit (or even the default position) Procedure surroundings: dark space, simulating the medical application environment. Page 76 In ailment the transverse resolution screening targets are horizontally shown, record the minimum length of two targets which might be Evidently acknowledged. Repeat the Procedure above for the transverse resolution screening targets at other depths. As shown in figure underneath. Axial resolution ... Website page seventy seven When utilizing the convex probe, hold the transverse resolution screening targets to notice: be displayed close to the midline. When using a linear probe with steer purpose, tend not to activate the steer perform Dp50rb login when carry out the transverse resolution examination. Zoom while in the location wherever the targets Positioned if required. The diameter with the focus on issue at a certain depth is equal on the transverse resolution at the depth. Webpage 78 5.

By continuing your take a look at on our website, you happen to be consenting to our use of cookies. Even so, you could change your cookie configurations Anytime.  Cookie choice Take and Progress

Cookies are very important to the appropriate performing of the web site. To help your knowledge, we use cookies to recall log-in details and provide secure log-in, gather stats to enhance site features, and supply information customized towards your pursuits.

Right after changing the CPU module, essential file has to be created Once more in accordance with the new MAC address and penned into HDD from the device. Or else, the configuration perform of the product are going to be shed. Soon after getting rid of the CPU module, Remove panhead screws with washers (12 M3X6) mounted on the leading device box, you normally takes off the board. Website page 118 Figure 8-29 Disassemble the Control Panel Assembly (1) Hold the higher fringe of user interface assembly, and open up up the user interface. Figure eight-thirty Disassemble the User interface Assembly (2) Immediately after eradicating 1 countersunk head self-tapping screw PT3X10 mounted to the user interface and acquire out the plug with the keyboard and the most crucial device connecting cables, you could potentially take out the user interface assembly.

If you prevent the scanning and the image seize, you'll want to power from the process and disconnect the procedure from the AC power source, then pull out AC ability cables. Web site 109: Battery Connecting Board

This handbook may well referring to information protected by copyright or patents and does not Express any license under the patent legal rights or copyright of Mindray, or of Some others. Site 9: Assertion

Reduce off cable ties connecting the main unit about the Screen by diagonal chopping pliers, and afterwards pull out the corresponding cable plugs.

Information Process Look at the battery periodically : a) Check if battery can be billed Generally when electric power-on: That The present capacity is a hundred% or capability raises after a brief time indicates which the battery is usually billed Ordinarily.

Report this page